PCB without plastic housing. 100309

PCB without plastic housing. SG-SLE 14-051 DC 24 V

  • MAYSER

 

  • The control unit is designed for signal processing of a pressure-sensitive protective device.
  • It evaluates the output signals of sensors with monitoring resistor 22k1.
  • The integrated output signal switching device (OSSD) transmits the evaluated safety signals directly to the downstream control.
  • The product complies with ISO 13849-1:2015 Category 3 PL e, so that the safety classification is retained, the downstream control must be of the same or a higher category